Site: KRP 2016
Sonic anemometer: Gill HS-50
Gas analyzer: LI-7200
Sampling rate: 20Hz
Postprocessing software version: EddyPro 6.2.0
Metadata file: embedded metadata used
Eddypro configuration file: processing_2017-05-18T131909_adv.eddypro
Biomet file used: KRP_2016_meteoEP.csv
Dynamic metadata used: dynamic_metadata_Kosetice2016.txt
Canopy height: dynamic
Measurement height: 2.6 m
SA North offset: 247 deg
GA tube length: 
	1.1.-27.4.11:00 - 1 m
	27.4.12:30-31.12. - 1.1 m
GA tube inner diameter:
	1.1.-27.4.11:00 - 9 mm
	27.4.12:30-31.12. - 5.33 mm
Sensor separation: 
	1.1.-27.4.11:00 - N: 0 cm, E: 0 cm, V: -21 cm
	27.4.12:30-14.6.10:30 - N: -1.5 cm, E: -3.5 cm, V: -14 cm
	16.6.12:00-31.12. - N: 2 cm, E: 0 cm, V: -14 cm
Axis rotation: double rotation
Time lag compensation: automatic - parameters from period 1.4.-31.10. computed: eddypro_KrP_timelag_opt_2017-05-18T131909_adv.txt
WPL: no (co2, h2O readings as mixing ratio)
Footprint estimation: Kljun 2004
Quality check flagging: Mauder and Foken 2004 - 0,1,2 system
Spectral correction:
- high-pass filtering: Moncrieff 2004
- low-pass filtering: Ibrom 2007 - parameters from period 1.4.-31.10. computed: eddypro_KrP_spectral_assessment_2017-05-20T180735_adv.txt
Random uncertainty: Finkelstein and Sims 2001

Notes:
27.4.2016 - new intake tube mounted
16.6.2016 - broken Licor replaced